| Type | [Photoelectric Sensor] Photoelectric Sensor |
|---|---|
| Light Source | Infrared-emitting diode |
| Amplifier accessory type | Amplifier Built-in Type |
| Detection distance [classification] | More than 10000 |
| Ambient Operating Temperature | −25~55 |
| Ambient Operating Humidity | 35~85 |
| Protective Structure | IP67 |
| Head maximum size width | 10.8 |
| Head maximum size height | 32.2 |
| Head maximum size, depth | 21 |
| Power Supply Voltage | VDC 10–30 |
| Output Format | Other |
| Operating Mode | Light ON / dark ON switchable |
| Connection Method | Integrated Cable Type |
| Cord Length | 5 |
| Timer | false |
| Response time (standard mode) | 1 |
| Laser class | None |
| Opening Angle | 3 |
| Detection Distance details | 15000 |
| Material of Cable Sheath | Polyvinyl chloride (PVC) |
| Material of Optical Surface | Plastic |
| Scope of Delivery of the One-Way System | Transmitter |
| Operation Agent-Safety Class | Safety class 3 |
| Housing Material | Metal |
| Setting Procedure | Manual adjustment |
| Type of Switch Function | Other |
| Type of Light | Infrared light |
| Construction Type Housing | Cuboid |
| Analogue Output -10 V ... +10 V | false |
| Pre Failure Notice | false |
| With Reflector | false |
| Number of Contact Energized Outputs With Signalling Function | 0 |
| Number of Semiconductor Outputs With Signalling Function | 0 |
| Max. Output Current | 100 |
| Max. Switching Distance | 15000 |
| Transmission Range of the Safety Field | 15 |
| Switching Frequency | 1000 |
| Rated Switching Distance | 15000 |
| Wavelength of the Sensor | 870 |
| AWG-Number | 25 |
| Degree of Protection (NEMA) | Other |
| Type of Interface for Safety Communication | Other |
| Explosion Safety Category for Dust | None |
| Explosion Safety Category for Gas | None |
| With Communication Interface CANOpen | false |
| With Communication Interface INTERBUS | false |
| With Communication Interface AS-Interface | false |
| With Communication Interface PROFIBUS | false |
| With Communication Interface SSI | false |
| With Restart Blockage | false |
| With Communication Interface RS-232 | false |
| Analogue Output 0 mA ... 20 mA | false |
| With Communication Interface RS-485 | false |
| With Other Analogue Output | false |
| With Communication Interface Ethernet | false |
| With Communication Interface RS-422 | false |
| Suitable for Safety Functions | false |
| With Communication Interface Analogue | false |
| With Monitoring Function Downstream Switching Devices | false |
| With Communication Interface Devicenet | false |
| Analogue Output 4 mA ... 20 mA | false |
| With Communication Interface SSD | false |
| Analogue Output 0 V ... 10 V | false |
| Number of Protected Contact Energized Outputs | 0 |
| Number of Protected Semiconductor Outputs | 0 |
| Type of Safety According To IEC 61496-1 | 1 |